What is meant by the temperature class for my pumps that are rated for explosive atmospheres? Pumps installed in potentially explosive atmospheres must be designed and operated in a way to limit their surface temperature based on the type of potentially explosive atmosphere. A reference for the requirements of electrical and nonelectrical equipment is the European Union (EU) ATEX Directive 2014/34/EU (Ex). Within this directive, one requirement is that pumps have a temperature class as stated in the explosion (Ex) rating on the nameplate. These are based on a maximum ambient temperature of 40 C (104 F). Refer to the manufacturer for higher ambient temperatures. The surface temperature on the pump is influenced by the liquid handled. The maximum permissible liquid temperature depends on the temperature class and must not exceed the values in Image 1. The temperature rise at the seals and bearings due to the minimum permitted flow rate is taken into account in the temperatures stated.